Endress Hauser Prosonic Fmu 860 Manual Espaol

08.12.2018
9 Comments

Cost effective device for sophisticated level measurement in liquids and bulk solids for up to 10m The Prosonic FMU42 sensor is suited for non-contact level measurement in fluids, pastes, coarse bulk material and flow measurement in open channels or at weirs. The two-wire or four-wire compact transmitter can be used in applications with storage tanks, agitators, on stockpiles and conveyor belts. The envelope curve can be shown on the on-site display for simple diagnosis. Tp link wireless n adapter driver download. Linearization function (up to 32 points) for conversion of the measured value into any unit of length, volume or flow rate.

• ProsonicFMU 860862Ultrasonic MeasurementOperating Instructions BA 100F/00/en/8-1010Software version 2.3/2.4 FMU 860 FMU 861 FMU 862 Hauser+EndressThe Power of Know How • Table of Contents Software-History 4 Notes on Safety 5 Safety Conventions and Symbols 6 1 Introduction....... 7 1.1 Features........ 81.2 Measuring System...... 91.3 Measuring Principle...... 11 2 Installation....... 13 2.1 Mounting the Prosonic FMU....

132.2 Electrical Connection..... 172.3 Technical Data....... 23 3 Controls........ 28 3.1 Prosonic Operating Matrix.... 283.2 Display and Controls: Prosonic FMU..

293.3 Operation via Universal HART Communicator DXR 275.. 313.4 Operation with Commuwin II.... 32 4 Level, Difference, Average Value... 34 4.1 Basic Settings.......

Utorrent turbo booster free download full version with crack. Serial Key: C1A8-A6A3-A09F-C1A8. Use provided ' Serial Key' below to register the program.

344.2 Basic Adjustment: Empty/Full Adjustment. 374.3 Linearization.......

Chapter 4: Level, Difference, Average Value Prosonic FMU 860.862. 34 Endress+Hauser. Resetting the transmitterDuring initial commissioning a reset to the values preset in the works (known as defaultvalues) should be made.By entering 333 (if operated via PROFIBUS-DP: 1) in matrix field V9H5 the default valuescan be reset. Ultrasonic measurement Time-of-Flight Prosonic FMU44 ©Endress+Hauser. The Prosonic FMU44 sensor is suited for non-contact level measurement in fluids, pastes, coarse bulk material and flow measurement in open channels or at weirs. Endress+Hauser announces AdEdge Water Technologies has joined its OEM Business Partner Program.

404.4 Linearization for Vessels of Any Shape.. 424.5 Level Difference Measurement for Screen Control....... 464.6 Level Measurement with Calculation of the Average Value....... 48 5 Flow......... 49 5.1 Basic Settings....... 495.2 Basic Adjustment...... 515.3 Setting the Totalizers......

Fmu

575.4 Flow Measurement and Back Water Alarm (Only after Selecting Operating ModeV8H0: 9 Back Water Alarm).... 58 6 Analogue Output...... 59 7 Relays........ 63 7.1 Relay Function Limit..... 657.2 Relay Function Alarm Relay.... 717.3 Relay Function Tendency.... 727.4 Relay Function Counting Pulses...

737.5 Relay Function Timing Pulses... 767.6 Relay Function Back Water Alarm.. 76 8 Measuring Point Entries.... 77 8.1 Refreshing Information on the Measuring Point. 778.2 Locking the Matrix......

Hauser

77 9 Diagnosis and Trouble-Shooting.. 79 9.1 Two Types of Fault: Alarms and Warnings.. 799.2 Fault Analysis.......

819.3 Suppression of Interference Signals... 849.4 Simulation........ 869.5 Exchanging the Prosonic FMU or a Sensor. 879.6 Repairs........ 87 10 Summary of All Calibration Modes..

89 11 PROFIBUS-DP-Interface.... 97 11.1 Synopsis........ 9711.2 Topology........ 9811.3 Adress, Termination...... 10111.4 Device database and type files... 10311.5 Cyclic data exchange.....

10411.6 Acyclic data exchange..... 107 Appendix A: Weirs and Flumes... 111 Appendix B: Application Parameter V0H3 122 Operating Matrix......

125 Matrix Prosonic FMU 860.... 126 Matrix Prosonic FMU 861.... 127 Matrix Prosonic FMU 862.... 128 Index........ 129 These Operating Instructions are written for thesoftware version 2.3/2.4 of the Prosonic transmitter.Version 2.4 is used for devices with a PROFIBUS-DPinterface only.

Prosonic FMU 860.862 Table of Contents Endress+Hauser 3 • Software History SW /BA Device and Software No. Devicerevision DDrevision Changes Remarks 1.0 / 1 1 No up/downloadbetween SW 1.xand SW 2.xpossible 1.1 /08.93 No change indocumentation 2.0 / 2 1 Extended functions 2.1 / No change indocumentation 2.2 / Extended functions 2.3/ Extended functions 2.4/12.01 PROFIBUS-DP introducedFor instruments without PROFIBUS-DP interface version 2.3 remains valid. Software History Prosonic FMU 860862 4 Endress+Hauser • Notes on Safety Approved usageThe Prosonic FMU 860.862 is an ultrasonic transmitter which, depending on theparticular version, can be used for the following measurement tasks: Flowrates in open channels and weirs Water levels Control of rakes and pumps Levels in silos and tanks Determining the volume or mass of contents on silos and tanks Mounting,commissioning,operation The transmitters Prosonic FMU 860, 861, 862 have been designed to operate safely inaccordance with current technical, safety and EU standards.